The world's largest single medical device market, with a route to market determined almost entirely by whether a legally marketed predicate exists.

Instrument
FD&C Act · 21 CFR 800–898
Authority
U.S. Food and Drug Administration, Center for Devices and Radiological Health
The framework

What this market demands.

The FDA classifies devices into three classes by risk, and the class largely determines the route. Most Class II devices reach the market through a 510(k) premarket notification demonstrating substantial equivalence to a legally marketed predicate. Novel low-to-moderate risk devices without a predicate may use the De Novo classification request. Class III devices generally require premarket approval, the most demanding route the agency operates.

As of 2 February 2026 the Quality Management System Regulation replaced the former Quality System Regulation in 21 CFR Part 820. The QMSR incorporates ISO 13485:2016 by reference, substantially harmonising FDA expectations with the standard already used elsewhere. The FDA has correspondingly retired the Quality System Inspection Technique in favour of an updated inspection programme.

For manufacturers outside the United States, an establishment registration and a designated US Agent are prerequisites rather than formalities. Neither is difficult; both are routinely left too late.

Classification

Where a device sits decides what it costs.

Classification is the single most consequential determination in the process, and the one most often inherited as an assumption instead of being established as a conclusion.

Class I
Low risk. Subject to general controls. The majority are exempt from premarket notification, though registration and listing obligations still apply.
Class II
Moderate risk. Subject to general and special controls. Most require a 510(k) demonstrating substantial equivalence to a predicate device.
Class III
High risk, or devices sustaining life. Generally require premarket approval (PMA), supported by valid scientific evidence including clinical data.
The pathway

The route to market, in order.

Steps can overlap, but they cannot meaningfully be reordered. Most delay comes from attempting one before the one before it is settled.

  1. Classify the device

    Identify the classification regulation and product code. This determines the route, the controls, and whether an exemption applies.

  2. Select the route

    510(k) where a predicate exists; De Novo where the device is novel but low-to-moderate risk; PMA where the device is Class III.

  3. Pre-submission

    Where the question is genuinely open, a Q-Submission puts it to the review division before the resources are committed, not after.

  4. Build the evidence

    Bench testing, biocompatibility, software documentation, cybersecurity and, where the route requires it, clinical data.

  5. Submit

    Prepare and submit through eSTAR, then manage the interactive review and any Additional Information requests.

  6. Register, list and maintain

    Establishment registration, device listing, US Agent designation for foreign manufacturers, UDI, MDR reporting and QMSR compliance.

Dates that matter

The calendar is part of the strategy.

Transitional deadlines have moved before and may move again. Treat these as orientation, not as a substitute for checking.

  1. 2 February 2026The Quality Management System Regulation took effect, incorporating ISO 13485:2016 by reference into 21 CFR Part 820 and replacing the former QSR.
What goes wrong

The failures we see most often.

None of these are exotic. They are ordinary decisions that were reasonable at the time and expensive in hindsight.

  • Selecting a predicate that is convenient rather than genuinely comparable in technology and intended use
  • Indications for use drafted more broadly than the supporting evidence can carry
  • Software and cybersecurity documentation treated as an appendix when the reviewer treats it as a focus
  • Assuming prior ISO 13485 certification alone satisfies QMSR without a gap assessment
  • Leaving establishment registration and US Agent designation until after clearance

This page describes a public regulatory framework and was last reviewed 2026-08. It is provided for orientation and is not regulatory advice for a specific device. Requirements and deadlines change, so please confirm anything time-critical before relying on it.